ORION ISS
EXECUTIVE RELAY MODULE
S2000-SP1 (ver. 1.56)
INSTRUCTION MANUAL
1 GENERAL TECHNICAL DATA
1.1 General
1.1.1 The S2000-SP1 Executive Relay Module (hereinafter referred to as the module) is
designed to operate as a part of fire alarm systems, intrusion alarm systems, and access
control systems. It operates under control of a fire and alarm console S2000 / S2000M or a
PC with installed Orion Pro software.
1.1.2 Within intrusion alarm systems and access control systems the module is designed to
control various executive devices (lamps, sirens, electromagnetic locks, etc.), to send alarms
to a Central Monitoring Station by means of opening relay contacts, and to cooperate with
other devices and systems on relay level. In fire alarm systems the module is designed to
generate a start pulse for a fire extinguishing control panel.
1.1.3 The module is to be mounted inside the premises and is destined for round-the-clock
operation.
1.1.4 The module must not be used in aggressive medium or dust condition, or in explosion-
hazardous premises.
1.1.5 The module is intended to be used at operating temperatures 30°С to +55°С.
1.2 Specifications
1.2.1 The module is to be supplied by an external power supply with output voltage
10.2 V dc through 28.4 V dc. It is recommended to use battery backed power supplies of RIP-
12 or RIP-24 series manufactured by the Bolid Company.
1.2.2 The module power consumption is no more than 2 W.
Vue de la page 0
1 2 3 4 5 6 7 8 9 10

Résumé du contenu

Page 1 - S2000-SP1 (ver. 1.56)

1 ORION ISS EXECUTIVE RELAY MODULE S2000-SP1 (ver. 1.56) INSTRUCTION MANUAL 1 GENERAL TECHNICAL DATA 1.1 General 1.1.1 The S2000-SP1 Executive R

Page 2

10 BOLID ONE YEAR LIMITED WARRANTY Bolid Company and its divisions and subsidiaries («Seller»), 4 Pionerskaya Str., Korolev 141070, Moscow Region, Ru

Page 3

2 1.2.3 The current consumed by the module (without regard to connected executive devices): – 140 mA max at 12 V (all relays are switched on); – 2

Page 4

3 the module receives a command “Switch On for a Time”, the relevant relay switches on, while on elapsing the activation time the relay is switche

Page 5

4 module itself (input number = 0). READY indicator shall flash with low duty cycle ratio. The module will return to the quiescent mode when the powe

Page 6

5 network controller for the relay. The values 9 (Lamp) and 10 (Alarm Output) of this parameter are special ones. If Initial Condition is equal

Page 7

6 2.2.3 Mount the module on the wall or within a cabinet in accordance with its Installation Manual (the module is to be mount closely to executive

Page 8 - ANNEX A

7 To activate the self-diagnostic mode, open the module top cover and press the tamper switch on the PCB in SSSL pattern, where “S” (“short”) stands

Page 9 - S2000-SP1

8 ANNEX A S2000-SP1 Overall and Mounting Dimensions

Page 10

9 ANNEX B S2000-SP1 Connection Diagram Main Power Supply+12V (+24V)0VRIP-12 (RIP-24)Backup Power Supply (optional)+12V (+24V)0VRIP-12 (RIP-24)NC17COM